Led city light inspection procedure
The LED street light power module must not only be designed in accordance with the above requirements, but must also undergo rigorous inspection procedures:
1. Control devices with constant voltage output function or constant current output function or both shall be tested with the safety standard GB19510.12/IEC61347-2-13.
2. For the control device that only has the function of controlling the logic change of LED brightness, darkness, flashing, color, etc., the GB19510.12/IEC61347-2-11 safety standard shall be used for inspection.
3. If a control device has both the above-mentioned functions, it shall be tested in accordance with the safety standards of GB19510.12/IEC61347-2-13.
Practice has proved that through scientific design and rigorous testing, it can not only ensure that the LED street light system is not damaged by lightning, but also eliminates the common mode and differential mode interference caused by lightning to the power supply equipment.